Questions regarding Modular ONE
Here you will find all answers to your questions about Modular ONE from Parador.
Areas of application
Both floors can be used for this application as they are very dimensionally stable.
Due to their suitability for wet rooms, Modular ONE and Modular ONE Hydron are also suitable for rooms where water can get onto the floor. Modular ONE offers protection for up to 100 hours in this case. If you prefer a waterproof floor, we recommend Modular ONE Hydron. This is 100% waterproof due to its product structure.
The light fastness of our resilient flooring has been tested according to test standard EN ISO 105-B02 and achieves at least level 6 (or higher) on the blue wool scale. We still cannot exclude slight colour changes in case of continuously high solar radiation. The strong solar radiation can cause small joints to appear at the plank transitions, but this is neither a problem nor a defect. By means of suitable shading you can keep the temperatures in the room and on the surface of the flooring within a range that is no problem at all for our floors.
If you decide not to follow our recommendations and provisions, any guarantee or warranty claims on the part of Parador are excluded.
Installation
Yes, both Modular ONE and Modular ONE Hydron floors are suitable for floating installation on hot water underfloor heating.
As a matter of principle, all new mineral substrates must always be heated before installing resilient floor coverings so that damaging moisture can no longer escape ("heat ready for installation"). The need to heat the substrate applies in all seasons, in winter and summer. The new screed must dry out for at least 21 days before heating is started.
We recommend that heating be carried out according to our "heating protocol" template or that it be carried out by a specialist company. Please observe additional information given by your screed layer and heating engineer.
Different rules apply for installation on electric underfloor heating systems, as these systems operate with higher surface temperatures.
Please note the following:
- Only install your floor covering on systems that have a temperature sensor and controller
- DO NOT install your floor covering on older electric underfloor heating systems (installed before 2000)
- DO NOT install your floor covering on night storage heaters
- the maximum surface temperature of 29 °C must not be exceeded
- A very fast heating process must be avoided
Modular ONE already has integrated footfall sound insulation thanks to the cork layer on the back, as has Modular ONE Hydron thanks to the acoustic backing.
When installing Modular ONE and Modular ONE Hydron, we nevertheless recommend the use of an underlay, as this compensates for slight bumps in the substrate and has a positive effect on the flooring's acoustics.
Please note that, even in cases in which the use of a PE film is not necessary for structural reasons or also appears unreasonable, the Parador PE film must be used in order to create a "smooth" laying surface. This ensures the overall expansion property (unlimited "movement" of the flooring).
Care and maintenance
The most important thing when it comes to value retention is to avoid damage from the outset. You can do this by fitting soft felt glides under chair and table legs as well as under furniture legs, for example, which are available in many shapes and colours from any DIY store. The castors on office chairs, file trolleys and roller containers should be fitted with soft treads/rollers (type W, EN 12529). In heavily used areas, you can additionally protect the flooring with protective mats from an office supply store. Avoid using tyres or protective caps made of black rubber, as these cause discolouration.
The following tips are important for retaining the value of your resilient floor covering:
- keep the relative humidity in the rooms between 35 and 60 %. This is not only optimal for the floor coverings themselves, but also for your well-being and health.
- prevent sand and dirt from entering, as both act like sandpaper. So-called cleaning zones or dirt-trapping mats in the entrance area help. Make sure that such mats have a non-dyeing rubber or latex backing.
- Always absorb liquids standing on the floor immediately.
- when cleaning the floor covering, wring out the mop well and wipe only damp.
- scouring agents, floor waxes, hot steam cleaners, polishes or mircofibre wipers are taboo for cleaning resilient floor coverings, as they can severely impair the appearance of the floor.
- Avoid direct and too intensive sunlight on the surface of the floor covering. A suitable form of light protection such as shutters or pleated blinds will help you to do this.
- when it comes to cleaning agents, you are on the safe side with the care and maintenance products from the Parador range.
For regular maintenance care, an ordinary basic or universal cleaner is completely sufficient.
Sustainability
Healthy living
The use of Modular ONE and Modular ONE Hydron contributes to a healthy indoor climate and healthy living.
Both floors are PVC and plasticiser-free, release extremely low emissions, formaldehyde emissions of no more than 0.05 ppm, and are certified to E1 in accordance with ISO 16000, where the maximum required emission is 0.1 ppm.
This classification makes these floorings one of the most environmentally friendly of their kind.
What else you should know
Yes, potentially. Two parameters are decisive for the occurrence (and permanent retention) of pressure points: pressure and exposure time. Very heavy furniture with a very small contact area, which is left in place for a long period, will leave pressure points behind on resilient floor coverings just as much as on other soft floor coverings. However, making the contact area larger with suitable underlayers (plastic or metal plate) can very effectively prevent this effect.
Yes, you can, but you should bear a few rules in mind. Heavy objects weighing more than 350 kg such as kitchen units and wardrobes require twice as big a gap to the wall on the opposite side because the floor can only expand to one side. Since such a large expansion joint is not always practical, we recommend that heavy objects and built-in furniture be assembled BEFORE installation and that the flooring only be installed up to under the base of the furniture. In this way, you can again maintain the usual expansion joint widths, and the flooring can be easily taken back up at any time. If necessary, it may be useful to take the position of heavy objects into account when planning the installation. Tip: gluing the end edges of the plank in the load areas prevents joints from opening up.
No, our floor coverings are very durable but not scratch-resistant. The scratch resistance of hard floor coverings is generally low, and there are no values or classifications for it. This is different for durability, where you can orientate yourself by the wear classes. However, a durable floor covering is quite capable of withstanding the abrasion caused by sand or dirt particles.
Yes, that is possible without any problems. However, the castors on office chairs, file trolleys and roller containers should be equipped with soft treads (type W, EN 12529). In heavily used areas, you can additionally protect the flooring with protective mats from an office supply store. Avoid using tyres or protective caps made of black rubber, as these cause discolouration.